Industrial textiles
Industrial textiles, selected around the application.
Explore base fabrics, coated textiles and fabricated product categories. Compare their roles, then specify the grade, construction and documentation needed for your application.
Silicone-coated fiberglass fabric
Silicone-coated fiberglass for flexible covers, insulation facings and protective textile assemblies.
- Mass per area
- 560 g/m²
- Thickness
- 0.42 mm

PU-coated fiberglass fabric
Polyurethane-coated fiberglass for insulation facings and fabricated textile components.
- Mass per area
- 460 g/m²
- Thickness
- 0.41 mm
- Width
- 1 / 1.2 / 1.5 m

Fiberglass fabric
Glass-fiber textiles for heat barriers, insulation layers and further fabrication.
- Mass per area
- 1920 g/m²
- Thickness
- 2 mm

Vermiculite-coated fiberglass fabric
Vermiculite-coated fiberglass for hot-work textiles and thermal-barrier constructions.
- Mass per area
- 1070 ± 50 g/m²
- Thickness
- 1.40 ± 0.05 mm
- Width
- 1000 / 1520 / 1550 mm

High-silica fabric
Silica-rich woven textiles for hot facings and thermal barriers.
- Mass per area
- 600 g/m²
- Thickness
- 0.65–0.7 mm
- Width
- 1250 mm

Welding blankets
Textile blankets for protection requirements around welding sparks and hot particles.
- Mass per area
- 280–1400 g/m²
- Thickness
- 0.2–3 mm

Industrial heat curtains
Textile curtain assemblies for industrial heat shielding and spark containment.
- Mass per area
- 710 g/m²
- Thickness
- 0.65 mm

Thermal insulation fabrics
Textile facings and covers for removable industrial insulation assemblies.
- Mass per area
- 215 ± 10 g/m²
- Thickness
- 0.21 ± 0.02 mm
Specifications
Technical specifications
Published reference models for comparison. These are third-party specifications; the exact grade and supply details are confirmed with your enquiry.
| Reference model | Mass per area | Thickness | Width / dimensions | Full specifications |
|---|---|---|---|---|
| GF430P-SI233-1015 · silicone-coated fabric | 560 g/m² | 0.42 mm | Not listed | View table ↗ |
| PU213-2005 · polyurethane-coated fabric | 460 g/m² | 0.41 mm | 1 / 1.2 / 1.5 m | View table ↗ |
| TGF1920 · texturized fiberglass fabric | 1920 g/m² | 2 mm | Not listed | View table ↗ |
| TGF1000-VE226-5008 · vermiculite-treated fabric | 1070 ± 50 g/m² | 1.40 ± 0.05 mm | 1000 / 1520 / 1550 mm | View table ↗ |
| SL600-1 · silica glass-fiber fabric | 600 g/m² | 0.65–0.7 mm | 1250 mm | View table ↗ |
| HT880 base · welding-blanket page reference | 280–1400 g/m² | 0.2–3 mm | 1 × 1 / 1.2 × 1.2 / 1.5 × 1.5 / 1.2 × 1.8 / 1.8 × 1.8 m | View table ↗ |
| PU213-2036 · reinforced curtain fabric | 710 g/m² | 0.65 mm | Not listed | View table ↗ |
| GF200P / AF110-6009 · metallized-film facing | 215 ± 10 g/m² | 0.21 ± 0.02 mm | Not listed | View table ↗ |
| GF600-AC210-3004 · acrylic-treated example | 19 oz/yd² | 0.023 in | 100 / 152 cm | View table ↗ |
Values relate to each named reference model or stated page range. Temperature conditions and source discrepancies are explained in the full tables.
Side by side
Compare roles, then compare grades.
Reference information explains material categories. Use the selected product’s own documentation to confirm specifications and any applicable certification.
| Material category | Construction | Typical applications | Selection considerations |
|---|---|---|---|
| Silicone-coated fiberglass fabric | Silicone; specify formulation, coated sides and coating mass | Removable insulation, Equipment protection, Flexible expansion joints | The base-fiber temperature alone does not establish a coated fabric’s service limit. |
| PU-coated fiberglass fabric | Polyurethane; specify formulation and coating coverage | Removable insulation, Equipment protection | A PU coating should not inherit the temperature rating of its fiberglass substrate. |
| Fiberglass fabric | Uncoated or processed finish; specify the required treatment | Removable insulation, Equipment protection, Flexible expansion joints | Fiber type, finish and construction affect suitability; the name “fiberglass” is insufficient. |
| Vermiculite-coated fiberglass fabric | Vermiculite-containing mineral coating; specify the formulation | Welding & hot work, Furnaces & boilers, Removable insulation | A mineral coating does not establish suitability for every molten-metal exposure. |
| High-silica fabric | Uncoated or treated variants; specify the finish | Welding & hot work, Furnaces & boilers, Removable insulation | Specify silica composition and operating limits from documentation for the selected grade. |
| Welding blankets | As required by the selected fabric and construction | Welding & hot work, Equipment protection | Welding protection and emergency fire-extinguishing blankets have different intended uses. |
| Industrial heat curtains | Selected for the exposed surface and environment | Welding & hot work, Furnaces & boilers, Equipment protection | Building fire separation and smoke-control requirements must be assessed separately from an industrial heat-curtain application. |
| Thermal insulation fabrics | Dependent on the hot-face or outer-cover role | Removable insulation, Furnaces & boilers, Equipment protection | A fabric facing alone does not establish an insulation system’s thermal performance. |